Skip to main content

Data center sensing

Data Center Liquid Cooling Sensors

Sensors for CDU, cold plate, direct-to-chip and immersion cooling systems, covering pressure, temperature, humidity, leak, level and vibration sensing.

What we measure

Sensor coverage for liquid cooling

Explore sensor technologies mapped to CDU · Cold Plates · Direct-to-Chip · RDHx · Immersion · Manifolds · Pump/Valve OEMs. Product application notes below identify where each sensor fits within this data center sub-system.

Available technologies

Sensors for Liquid Cooling

35 products · 6 categories

Not sure what you need? Tell us about your liquid cooling application and our team will recommend the right sensors.

Telaire

Wet/wet differential pressure transmitter

Applications

  • CDU loop ΔP across cold plates (flow-blockage detection)
  • Pump ΔP for wear and cavitation trending
  • Strainer / coolant-filter ΔP monitoring
Type
Wet/wet differential
Media
Glycol, water, oil (316 SS wetted)
Output
4–20 mA

Custom variant

Glycol-compatible wetted materials (EPDM seals) as standard; optional NPT and G-thread process connections; extended-range version to 300 psid for primary-loop headers.

NovaSensor

NovaSensor NPI/IPT Harsh-Media Family

Applications

  • CDU coolant-loop pressure (primary and secondary)
  • Glycol fill / leak-down monitoring on closed loops
Range
1 – 15,000 psi
Output
4–20 mA, 0–5/10 V, I²C, SPI
Accuracy
±0.25% FS
NovaSensor

Low-Cost Media-Compatible P+T

Applications

  • CDU primary and secondary loop P+T
  • Cold-plate inlet/outlet P+T (one device replaces two)
  • Chilled-water and immersion-loop P+T
  • CDU filter ΔP and pump-health ΔP
Tech
PT1907 MEMS die, no oil fill
Range
15 – 600 psi
Output
I²C, SPI, 4–20 mA, Analog, SENT

Custom variant

LCMC is a platform, not a single SKU — specify range, interface (I²C / SPI / 4–20 mA / SENT), process connection and cable pigtail per CDU / compressor integration. No oil-fill keeps it glycol- and refrigerant-safe.

NovaSensor

Digital media-isolated pressure

Applications

  • High-pressure coolant loops on CDU primary lines and immersion manifolds (digital I²C readout)
Range
2.5 – 300 psi (A/G)
Linearity
±0.25% FSO (BFSL)
Interface
I²C 14-bit

Custom variant

Optional Hastelloy C diaphragm for aggressive dielectric coolants and chemistries where 316L is attacked; custom process-port thread patterns on request for OEM CDU integration.

Amphenol Sensors

High-pressure P+T with stainless-steel diaphragm

Applications

  • Coolant-loop P+T in one port (P + T combined)
  • CDU inlet/outlet P+T on high-pressure primary loops
Range
10 – 350 bar (145 – 5000 psi)
Diaphragm
Stainless steel — universal media
Feature
P + T in one sensor body
Thermometrics

Waterproof IP68 overmolded NTC

Applications

  • Immersion-rated coolant temperature on CDU and chilled-water loops (JIC stainless variant)
Protection
IP68 waterproof overmold
Range
−50 to +105 °C (+125 °C ≤ 6 h)
Thermistor
10 kΩ NTC

Custom variant

Longer probe lengths (6″ / 12″) for duct insertion; threaded SS housing for pipe immersion; networked multi-probe cable (up to 8 probes / run) for rack-row monitoring.

Thermometrics

Screw-fixed surface NTC

Applications

  • Ring-terminal-mount NTC on CDU pump cabinets and busbar lugs — coolant-line surface temperature where direct contact at a screw-terminal is needed
Operating
−40 to +125 °C
R @ 25 °C
5K / 10K / 20K / 50K / 100K Ω
Form factor
Ring-terminal screw-mount
Thermometrics

Compact NTC for liquid loops

Applications

  • Liquid-cooling loops: rack CDU inlet/outlet temperature
  • BESS secondary-loop coolant temperature
Operating
−40 to +100 °C
R @ 25 °C
2828 Ω (β 3975 K)
Thread / body
M12 × 1.5, stainless
Thermometrics

Surface-stick NTC (flat / pipe / cable)

Applications

  • Stick-on coolant-pipe skin temperature where retrofit on existing CDU lines is needed (no penetration)
Operating
−30 to +70 °C
R @ 25 °C
9983 Ω (typ)
Mounting
Pressure-sensitive adhesive
Thermometrics

Inline NTC with barb fittings

Applications

  • Chilled-water coil inlet/outlet temperature
  • CDU coolant-loop inline temperature with barb fittings (no weld-in)
Operating
−40 to +120 °C
R @ 25 °C
10 kΩ ±1.5%
Interface
SAE J-1231 / Triple-Barb
Thermometrics

Acid/moisture-resistant coated chip

Applications

  • Coolant and immersion-fluid temperature in harsh environments (acid / moisture exposure)
  • Direct-immersion temperature in two-phase / dielectric coolants where standard NTC encapsulants degrade
Operating
−40 °C to +190 °C
Compliance
AEC-Q200 Rev D · RoHS · REACH
Features
Shock-resistant · silver-migration resistant
Telaire

Dew-point / enthalpy / wet-bulb

Applications

  • Outdoor CDUs where dew-point / wet-bulb matters for condensation control
  • Extended-range ambient monitoring above standard RH/T limits
Operating env
−40 to +60 °C, 0–99% RH
Output
4–20 mA, 0–5 V or 0–10 V
Measurands
Dew Pt · Enthalpy · Wet Bulb · Dry Bulb
Telaire

OEM board-level T+RH

Applications

  • Liquid-cooled rack environmental monitoring — RH+T inside CDU enclosures and adjacent dry-rack air space for condensation-risk surveillance
RH accuracy
±2.0% RH (20–80%)
Temp accuracy
±0.5 °C (14-bit)
Output
I²C or PDM
Amphenol

Epoxy-hardened waterproof transmitter

Applications

  • CDU condensation-risk monitoring at equipment drip points
RH accuracy
±2% RH (30–95%) @ 25 °C
Feature
Withstands 100% saturation
Output
4–20 mA, 0–5 V or 0–10 V
Thermometrics

RLDS-B / RLDS-P / RLDS-E controllers

Applications

  • CDU under-rack leak loops; primary/secondary loop leak containment
Type
Rope-style conductive leak detection
Family
RLDS-B / RLDS-P / RLDS-E controllers
Cable support
Up to 1,500 m (Elite positioning)
Thermometrics

Point/spot water-detection sensor

Applications

  • CDU and primary-loop drip-tray water detection — dry-contact alarm back to leak-monitor or BMS
Sensing R
510 kΩ ±3% (1/4 W)
Supply
5 VDC recommended
Operating
−40 to +85 °C
Rochester

Capacitive liquid-level transmitter (with TLL head)

Applications

  • CDU reservoir level (non-conductive coolants)
Probes
500 / 1000 mm; field-cut to length
Liquids
Diesel, kerosene, non-conductive fluids
Supply
9–36 VDC (80 V OVP, reverse-polarity)
Output
Resistive / 0–5 V / 4–20 mA (TLL head)
Accuracy
±1% FS
Cert.
CE, RoHS; IP65 head
Rochester

Top-mount magnetic dial level gauge (mechanical)

Applications

  • CDU glycol reservoir local readout
Type
Top-mount 5-bolt magnetic level gauge
Accuracy
±6 % (6700 base), ±7 % (Adjustable)
Variants
6741 / 6781 + TwinSite® sender
Rochester

Cellular radar tank monitor (remote telemetry)

Applications

  • CDU reservoir / coolant tank fill-level tracking on remote / edge sites — cellular reporting without a DCIM integration
Sensing
Radar — non-invasive tank level
Network
CAT-M1 / NB-IoT cellular (FCC)
Battery life
Up to 10 years (ATEX logger)
Certifications
ATEX / IS; UL 913 Class I Div 1, Zone 0
Rochester

Guided-wave radar level transmitter

Applications

  • Large-reservoir CDU / thermal-storage tank level where foam or vapor defeats ultrasonic
Sensing
Guided wave radar (TDR); no moving parts
Range
Up to 3 m; <2 mm resolution
Output
0.5–4.5 V / 4–20 mA options
Sealing
IP6K9K
Rochester

Custom float and leak switches (point level)

Applications

  • CDU reservoir hi/lo float alarm
  • Point leak-switch under manifolds and CDUs
Type
Custom-engineered float & leak switches
Capabilities
Multi-level, side-mount, continuous, P+T combos
Mfg.
IATF 16949 — Coppell, TX

Custom variant

Built-to-order: specify stem length, float material, switch action (N.O./N.C.), process fitting, cable and connector. Rochester Quick-Turn (Coppell, TX) builds from the 9871 / 9872 / 9873 / 9875 families — IATF 16949 North-American manufacturing, OEM-volume capable.

SSI

Non-contact ultrasonic level

Applications

  • Non-contact level in CDU reservoirs where immersion probes are unwanted
Max depth
32" diesel / 24" gasoline
Accuracy
±0.125"
Outputs
3-wire resistive · voltage · DFT-110
SSI

T + Ultrasonic + Level + Concentration

Applications

  • CDU glycol concentration monitoring — one device reports level, temperature and glycol concentration over a single interface
Concentration
0–50%, ±3%, 0.25% res.
Level
20–850 mm, ±3 mm
Comm
J1939 CAN
Wilcoxon

High-MTBF industrial accelerometer

Applications

  • CDU pump-bearing vibration monitoring — early detection of impeller imbalance, cavitation and bearing wear before coolant-flow loss reaches the racks
Sensitivity
100 mV/g ±5%
Response
0.5 – 14,000 Hz
Max temp
120 °C
Compliance
API 670; CSA / ATEX / IECEx variants
IMI

Echo® sensor + EchoPlus® wireless

Applications

  • CDU-pump vibration trending without running conduit to the pump skid
System
Wireless sensor + EchoPlus® JB + Receiver
Measures
Peak/RMS vel, accel, crest factor
Integration
Modbus®
Piher

Flange-mount gear-tooth speed sensor

Applications

  • CDU-pump RPM feedback for closed-loop flow control
Supply
4–24 VDC (two-wire)
Max speed
12 kHz fwd / 40 kHz (A/B)
Operating
−40 to +125 °C
Piher

Open-loop Hall-effect current sensor

Applications

  • Open-loop current sensing on CDU pump and heater circuits (wire-through)
Range
±25 A – ±1,000 A
Output
Ratiometric 0.5 – 4.5 V
IP
IP67 / IP69K

Custom variant

Split-core (clamp-on) retrofit variant for installation on live feeders without disconnecting wires; custom window geometry for non-standard busbar sections on request.

Piher

Non-contact Hall-effect rotary

Applications

  • CDU valve-position feedback on motorized ball valves (non-contact, 50 M-cycle life)
Linearity
±1% (±0.5% on request)
Range
Programmable 50°–360°
Supply
5 V ±10% or 7–32 V
All Sensors

Stainless-steel piezoresistive — high media compatibility

Applications

  • CDU primary-loop high-pressure media-compatible monitoring (G 1/8 in or weld-ring port; PG/EG and dielectric coolant compatible)
Tech
Piezoresistive (SS 316/316L wetted)
Range
200 mbar – 35 bar (A / G / V)
Output
mV (1.5 mA constant-current)
All Sensors

Stainless-steel piezoresistive — analog + I²C

Applications

  • CDU pressure monitoring with simultaneous I²C telemetry and analog control-loop output (SS-wetted, 13-bit resolution)
Tech
Piezoresistive + ASIC (SS 316/316L)
Range
200 mbar – 35 bar / 3 – 500 psi
Output
0.5–4.5 V ratiometric + I²C
Thermometrics

Non-invasive pipe-skin NTC clips

Applications

  • Non-invasive coolant-pipe temperature on CDU primary and secondary loops (no break-in retrofit)
  • Chilled-water plant pipe-skin temperature trending across multiple pipe diameters
  • Drop-in retrofit on existing whitewater and TCS lines without draining the loop
Pipe OD range
8 – 54 mm (multiple clip sizes)
Range
−40 to +150 °C
Mount
Spring-clip, no break-in

Custom variant

Family covers OD 12.7 / 18 / 22 / 28 / 35 / 42 / 54 mm with single connector standard (M12 A-coded). Thermally-conductive non-marring TPE pad compatible with PG/EG and dielectric coolants.

Telaire

SIP through-hole T+RH module

Applications

  • SIP through-hole T+RH integrated on CDU control PCBs and BMS boards for board-level condensation prevention
RH accuracy
±2.0% RH (20–80%)
Output
I²C or PDM
Package
4-pin SIP through-hole
Thermometrics

NTC probe — water-ingression resistant

Applications

  • Outdoor CDU coolant lines exposed to weather, coastal / humid sites (UV + chloride + sulfate resistant per HACT testing)
Type
NTC thermistor probe; HACT-tested
Resistance
Standard NTC curves (5K / 10K / 50K Ω)
Range
−40 to +150 °C
i2s

Compact media-isolated, stainless-steel technology proven in harsh environment

Applications

  • CDU primary and secondary loop pressure on PG/EG and dielectric coolants (water, glycol)
Ranges
0–10 bar / 0–40 bar (a); gage possible
Total error band
±1.0% FSS
Output
0.5–4.5 V ratiometric · 4–20 mA
Thermometrics

Coolant immersion probe — brass housing

Applications

  • CDU coolant immersion temperature on water / glycol loops — brass-housing thread-in alternative to clip-on surface sensors when an immersion probe is preferred
Type
NTC immersion probe (brass)
Resistance @ 25 °C
2129 Ω ± 4.87%
Range
−30 to +150 °C